Price
$1,570.00 CAD
Stock
Out of Stock
Does not ship to OH, United States

  • Model - Type 0460
  • Circuit Function - H (5/2-Way Valve, Servo-Assisted, Impulse Version)
  • Response Time - 15 milliseconds / 15 milliseconds

Specifications

Ambient Temperature Range

  • 0° to 50° C (32° to 122° F) - Typical 0460
  • 0° to 55° C (32° to 131° F) - Typical 6524/6525/6526/6527
  • -10° to 55° C (14° to 131° F) - Typical 5470

Approvals & Certifications

  • 3 According to VDE 0580
  • EEx ia IIC T6

BSP Connection

  • G 1/4” Female - Typical 0460
  • G 1/8” Female - Typical 6526 / 6527 / 5470

Communication

  • CANopen
  • DeviceNet
  • Ethernet I/P
  • FOUNDATION Fieldbus
  • Internal Bus Extension by PROFIBUS DP
  • Modbus TCP
  • PROFIBUS DP
  • PROFINET IO
  • Transmission Rate: 1.5, 3, 6, 12 MBaud
  • Transmission Rate: 9.6, 19.2, 93.75, 187.5, 500 KBaud

Current

  • Total Current (with Common & Multipin Connection): 3 A, Max.
  • Total Current (with Fieldbus Connection): 200 mA Specification Base Current PROFIBUS-DP & DeviceNet

Diameter

  • Pneumatic Module (Plug-In Coupling): 0.314” (8 mm) - Typical 6526/6527
  • Service Port 2 (A), 4 (B): Push-In Connection 0.25” (6 mm) - Typical 0460/5470

Duty Cycle

  • Continuous Operation 100 % ED

Electrical Connectors

  • At the Valve: Grid Spacing 2.54 mm - Typical 6524/6525 (2 x 3/2-Way Valve)
  • At the Valve: Grid Spacing 5.08 mm - Typical 6524/6525 (3/2-Way Valve), 5470
  • At the Valve: Rectangular Plug (4-Pole Male)
  • At the Valve: Rectangular Plug 2-Pin - Typical 6524/6525 (3/2-Way Valve)
  • At the Valve: Rectangular Plug 3-Pin - Typical 6524/6525 (2 x 3/2-Way Valve)
  • Common Connection (Parallel Connection)
  • M12 Circular Plug (4-Pole Male)
  • Multipin (D-Sub, 25-Pole)
  • Push-In Connection
  • Screw Terminal - Connection Via Individual Standard Wire
  • Tag Connector - Typical 6526/6527 (According to DIN EN 175301-803 [Previously DIN 43650] Form C), 5470 (According to DIN 43 650 Form C)

Enclosure, Body Material

  • Aluminum - Typical 0460
  • Polyamide (PA) - Typical 6524/6525/6526/6527/5470

Environmental Protection

  • IP20
  • IP54
  • IP65

Flow Rate

  • 200 L/minute (Circuit Function H-Impulse, L & N) - Typical 0460/6524/6525
  • 300 L/minute - Typical 0460/6524/6525/5470
  • 700 L/minute - Typical 6526 / 6527

Function

  • Circuit Function

Materials of Construction

  • Adapter Plate, Pneumatic Connection: 304 Stainless Steel 1.4301 - AirLINE Quick
  • Adapter Plate: Anodised Aluminum - AirLINE Quick
  • Pneumatic Connection: Brass Nickel-Plated - AirLINE Quick
  • Valve Internal: Ultramid

Media

  • Compressed Air - Typical 0460 (Lubricated & Non-Lubricated Dry), Typical 5470
  • Lubricated Dry Air - Typical 6524/6525/6526/6527
  • Neutral Gases - Typical 6524/6525/0460/5470 (5 µm Filter), Typical 6526/6527 (10 μm Filter)
  • Non-Lubricated Dry Air - Typical 6524/6525/6526/6527

Mounting

  • With 2 Screws M2 x 20 - Typical 6524/6525 (3/2-Way Valve)
  • With 2 Screws M2 x 28 - Typical 6524/6525 (2 x 3/2-Way Valve)
  • With 2 Screws M3 x 30 - Typical 6526/6527

Mounting Position

  • Upright - Typical 6524/6525/6526/6527 (Preferably with Actuator), 5470 (Preferably with Pilot Valve)

Nominal Power

  • 0.8 W - Typical 6524/6525 (3/2-Way Valve, 2 x 3/2-Way Valve - 2 times with Reduction of Power Consumption)
  • 1 W - Typical 0460

NPT Connection

  • 1/4” NPT Female - Typical 0460
  • 1/8” NPT Female - Typical 6526 / 6527 / 5470

Operating Voltages

  • 110-120 Vdc - Typical 5470
  • 220-240 Vdc - Typical 5470
  • 24 Vdc

Orifice Size

  • 2.5 mm - Typical 0460
  • 4 mm - Typical 6524/6525/5470
  • 6 mm - Typical 6526 / 6527

Override

  • Manual Override - Typical 6524/6525/0460/6526/6527

Power

  • Rated Power: 1 to 2 W - Typical 6526/6527
  • Rated Power: 1 to 3 W - Typical 5470
  • Rated Power: 1 W - Typical 0460/6524/6525

Pressure Range

  • bar: -7 to 10
  • kPa: -700 to 1,000
  • psi: -101.5 to 145

Process Temperature

  • -10° to 50° C (14° to 122° F) - Typical 5470

Response Time

  • 12 to 20 milliseconds According to ISO 12238 - Typical 6524/6525 (Opening), 6526 / 6527 (Opening & Closing)
  • Closing: 15 to 20 milliseconds According to ISO 12238 - Typical 0460
  • Closing: 20 to 28 milliseconds According to ISO 12238 - Typical 6524/6525
  • Opening: 15 milliseconds According to ISO 12238 - Typical 0460

Seat / Seal Material

  • Seal: fpm - Typical 6524/6525
  • Seal: NBR

Tolerance

  • Voltage: ± 10 %

Valves

  • Number of Valve Functionalities Per Unit: 24, Max.

Voltage

  • 24 Vdc - Typical 6526 / 6527

show more