Specifications
Applications
- Chemical Injection Assurance
- Compressor Leakage
- Cooling Water & Fluids
- Leak Detection
- Lubricant Flow Assurance
- Nitrogen Purge Verification
- Ventilation Verification
Approvals & Certifications
- SIL 2 Compliance Rating
- ATEX: Non-Incendive for Gas & Dust, Zone 2
- CE Marking: Complies with Canadian Electrical Code Requirements of ANSI/ISA 12.27.01-2011 as a Single Seal Device
- CRN: Complies with Canadian Electrical Code Requirements of ANSI/ISA 12.27.01-2011 as a Single Seal Device
- EAC TR CU Russia: II 3 G Ex NA IIC T4 Gc, I 3 D Ex Tc IIIC T81° C Dc IP64
- FM, FMc: Non-Incendive, Class I, Div. 2, Grade A, B, C, D, Class II, Div. 2, Groups E, F, G, Class III, T4 at Ta=71° C, Typical 4X
- IEC 61508: (SIL) SIL 2 Compliant, Safe Failure Fraction (SFF) 90 %
- IECEx: Non-Incendive for Gas & Dust, Zone 2
Communication
- Serial: RS-232C I/O
Delay Time
- Trip Point Time Delay: User Settable for 0 to 65,000 seconds
Display
- 10 LED Display Array & Two-Button Key Pad
Electrical Connectors
- Fixed, Watertight Cable Gland to Wire Pigtail, 15 feet (5 metres) Length
- M12 Connector
Electrical Rating
- 1 A at 120 Vac
- 1 A at 24 Vdc
Enclosure, Body Material
- Aluminum
- Silicone
- Stainless Steel
Environmental Protection
- IP64
- IP65
- IP66
- IP67
- NEMA 4X
- Typical 4X
Hysteresis
- Trip Point Hysteresis Control: 0 To100 % of Span
Input Power
- 21.5-30 Vdc
- 24 Vdc
- Maximum
Insertion 'U' Length
- 2” (50 mm)
- Variable Insertion Depth, Compression Fitting with Teflon or Metal Ferrule: 6” (150 mm)
Load Resistance
- Fault Indication Per NAMUR NE43 Guidelines: Max.
Media
- Gas
- Liquids
NPT Connection
- 1/2” NPT Male
- 1/4” NPT Male
Operating Pressure - Sensor
- psi: 2,000 (kPa: 13,800, bar: 138)
Operating Temperature
- -40° to 71° C (-40° to 160° F)
Operating Temperature - Sensor
- -40° to 121° C (-40° to 250° F)
Output
- 4-20 mA
Principle of Operation
- Thermal, Calorimetric
Repeatability
- ± 0.5 % of Reading
Response Time
- 4 seconds (1 Time Constant)
Set Point Range
- Air: 0.25 to 400 sfps (0.076 to 122 mps)
- Water: 0.01 to 0.5 FPS (0,003 to 0,15 mps)
Switch Type
- SPDT
Temperature Coefficient
- Gas: Max.
- Liquid: Max.
Wetted Materials
- 316L Stainless Steel
- Hastelloy C-22 Thermowells