ST100L Mass Flow Meter
Brand: Fluid Components International LLC (FCI)The FCI Model ST100L is an in-line, spool piece gas flow meter that combines best-in-class transmitter/electronics and superior calibration to provide a truly state-of-the-art gas flow meter for industrial process and plant applications with line sizes up to 2" (50 mm).
Features- Compatible with more than 200 gases
- Direct mass flow measurement
- Dual function – flow and temperature
- Temperature service to 121° C (250° F)
- No moving parts, non-clogging
- Best-in-class digital / Graphical readout
- Multiple Analog outputs
- Extensive Bus communications options
- Line sizes ≤ 2" (50 mm)
- Agency approvals on full instrument
- On-board data logger
Specifications
Accuracy
- Gas Specific Calibration & SpectraCal™ Gas Equivalency: ± 0.5 % of Full Scale
- Gas Specific Calibration: ± 0.75 % of Reading
- SpectraCal™ Gas Equivalency: Typically ± 4 % of Reading
- Temperature (Display Only, Flow Rate Must be greater than 5 AFPS [1.5 m/sec]): ± 1.1° C (± 2° F)
Applications
- Industrial Process Control
- Plant Applications
Approvals & Certifications
- ATEX: Zone 1, II 2 GD Ex d IIC T4
- CE
- CPA
- CRN
- EAC TR CU Russia
- FM, FMc (Canadian): Class I, Div. 1, Hazardous Locations, Groups B, C, D, E, F, G
- GOST-R, GOST-K
- IECEx: Zone 1, II 2 GD Ex d IIC T4
- INMETRO
- NEPSI
Approvals & Certifications
- AS 9100
- ISO 9001
Cable Length
- Remote Transmitter Configuration (Interconnecting Cable): up to 1,000 feet (300 metres)
Cable Material
- PVC Jacketed
- Teflon Jacketed
Communication
- Ethernet
- FOUNDATION Fieldbus H1
- HART (Comes Standard with Analog Outputs, V7 Compliant)
- Modbus Via RS-485
- On-Board Data Logger
- PROFIBUS PA
- USB
Conduit Connection
- 1/2” NPT Female
- M20 x 1.5 Female
Delay Time
- 0 to 99.9 seconds
Display
- Large 2” x 2” (50 x 50 mm) LCD, Digital Plus Bar Graph & Engineering Units
Enclosure, Body Material
- Transmitter / Electronics & Local Enclosure (Remote Configuration): Polyester Powder-Coated Aluminum
- Transmitter / Electronics: Stainless Steel
Environmental Protection
- IP66
- IP67
- NEMA 4X
Flange Material
- 316L Stainless Steel
- Carbon Steel
- Hastelloy C
Flange Size - 1-1/2” (DN 40)
- 1-1/2” (DN 40) - 150# ANSI
- 1-1/2” (DN 40) - 300# ANSI
- 1-1/2” (DN 40) - PN 40 (DIN)
Flange Size - 1” (DN 25)
- 1” (DN 25) - 150# ANSI
- 1” (DN 25) - 300# ANSI
- 1” (DN 25) - PN 40 (DIN)
Flange Size - 2” (DN 50)
- 2” (DN 50) - 150# ANSI
- 2” (DN 50) - 300# ANSI
- 2” (DN 50) - PN 16 (DIN)
- 2” (DN 50) - PN 40 (DIN)
Flange Size - 3/4” (DN 20)
- 3/4” (DN 20) - 150# ANSI
Flow Rate
- Air at 21.1° C (70° F) & psi a: 14.7 (kPa: 101.3, bar: 1.013) at 0° C (32° F): 0.0062 to 1,850 scfm (0.01 to 3,140 Nm³/hour)
Hysteresis
- 00.0 to 99.9 Counts
Indication
- Relay/Alarm Status
Input
- Auxiliary Input: Two 4-20 mA Input Channel
Input Power
- 24 Vdc (19.2-28.8 Vdc)
- 85-265 Vac
Length
- In-Line Body Typical: 9” to 18” (229 to 457 mm)
Media
- Air
- Gases (Compatible with the Flow Element Material)
Mounting
- Integral Mounting
- Remote Mounting
Mounting Position
- Horizontal, Flow Right-to-Left or Left-to-Right
- Vertical Down or Up
NACE & NIST
- Calibration: Performed on NIST Traceable Facility
NPT Connection
- 1” NPT Female
- 1” NPT Male
- 1-1/2” NPT Female
- 1-1/2” NPT Male
- 2” NPT Female
- 2” NPT Male
- 3/4” NPT Female
- 3/4” NPT Male
Operating Pressure
- psig: 250 (kPa: 1,724, bar: 17.24)
Operating Temperature
- Flow Element: -40° to 121° C (-40° to 250° F)
- Flow Transmitter/Electronics: -18° to 65° C (0° to 150° F)
Output
- Standard Output Plus Two (2) 2 A SPDT Relays
- Three (3) 4-20 mA, 0 to 1 kHz, or 0 to 10 kHz Pulse/Frequency
Output Function
- Fault Indication Per NAMUR NE43 Guidelines, User Selectable for High (> 21.0 mA) or Low (21.0 mA) or Low (21.0 mA) or Low (21.0 mA) or Low (21.0 mA) or Low (21.0 mA) or Low (21.0 mA) or Low (21.0 mA) or Low (21.0 mA) or Low (21.0 mA) or Low (21.0 mA) or Low (21.0 mA) or Low (21.0 mA) or Low (21.0 mA) or Low (21.0 mA) or Low (21.0 mA) or Low (< 3.6 mA)
Pipe Connection
- 1” Pipe
- 1-1/2” Pipe
- 2” Pipe
Pipe Schedule
- Schedule 40
- Schedule 80
Process Temperature
- -40° to 121° C (-40° to 250° F)
Repeatability
- Flow: ± 0.5 % of Reading
- Temperature (Flow Rate Must be greater than 5 AFPS): ± 1° C (± 1° F)
Rotation
- Display is Electronically Rotatable: 90° Increments to Optimize Viewing Angle
Sensor, Probe Material
- Flow Element: 316L Stainless Steel
- Flow Element: Hastelloy C-276
Sensor, Probe Style
- In-Line (F, S Style)
Sensor, Probe Type
- Precision, Wide-Ranging Platinum RTD
Temperature Coefficient
- Flow: ± 0.015 % of Reading/°F up to 250° F [ ± 0.03 % of Reading/°C up to 121° C], Max.
Temperature Range
- Commensurate with Element: 0° to 121° C (32° to 250° F)
Tube Connection
- 1” Tube with 1/8” or 1/4” Injection Tube Reducer & Built-In Vortab Flow Conditioner
Turndown
- Factory Set & Field Adjustable: 10: 1 to 100: 1 within Calibrated Flow Range
Welded Connection
- 1” Butt Weld End
- 1-1/2” Butt Weld End
- 2” Butt Weld End
- 3/4” Butt Weld End
Wetted Materials
- 316L Stainless Steel
- Hastelloy C-276
- Industry process control
- Plant applications