Price
$535.00 CAD
Stock
25+ In Stock
Does not ship to OH, United States

  • Version - Chlorine Sensor with 3 Electrodes
  • Measuring Range - 0.01 to 20 ppm
  • Output - 4-20 mA
  • Electrical Connection - 5-Pin M12 Male Connector

Specifications

Ambient Temperature Range

  • Operation & Storage (Electrolyte): 5° to 35° C (41° to 95° F)
  • Operation & Storage (Probe): 5° to 40° C (41° to 104° F)

Applications

  • Monitoring Absence of Chlorine in Reverse Osmosis Systems - Chlorine Sensor ”Trace”
  • Monitoring Chlorine (At Fluctuating PH - Chlorine Sensor with 3 Electrodes, at Constant PH - Chlorine Sensor with 2 Electrodes)

Approvals & Certifications

  • CE
  • EU Directives

Cap Material

  • Membrane Cap: PVC

Consumption

  • Current: 20 mA Approximately - Chlorine Sensor ”Trace”
  • Current: 4 mA Approximately, Max.

Electrical Connectors

  • 4-Pin Fixed Hermaphroditic Connector - Chlorine Sensor ”Trace”
  • 5-Pin M12 Connector (Male) - Chlorine Sensor with 3 Electrodes, Chlorine Sensor with 2 Electrodes
  • Screw Terminal

Flow Rate

  • Fluid: 15 to 30 L/hr

Humidity

  • < 90 % Relative Humidity, without Condensation

Loop Impedance

  • 50 ohms at 12 Vdc, Max.
  • 900 ohms at 30 Vdc, Max.

Materials of Construction

  • 316Ti Stainless Steel, 1.4571 - Chlorine Sensor ”Trace”, Chlorine Sensor with 3 Electrodes
  • Halide Reference Electrode: Silver
  • Membrane Holder: Stainless Steel
  • PVC - Chlorine Sensor ”Trace”
  • PVC-U - Chlorine Sensor with 3 Electrodes, Chlorine Sensor with 2 Electrodes
  • Working Electrode: Gold

Measuring Range

  • 0.005 to 2 ppm - Chlorine Sensor ”Trace”
  • 0.01 to 20 ppm - Chlorine Sensor with 3 Electrodes, Chlorine Sensor with 2 Electrodes

Media

  • Water (6.5 to 9 PH - Chlorine Sensor ”Trace”, 4 to 9 PH - Chlorine Sensor with 3 Electrodes, 6 to 8 PH - Chlorine Sensor with 2 Electrodes)

O-Ring Material

  • Sealing: NBR

Operating Voltages

  • 12-30 Vdc, Filtered & Regulated - Chlorine Sensor with 3 Electrodes, Chlorine Sensor with 2 Electrodes
  • 9-30 Vdc, Filtered & Regulated - Chlorine Sensor ”Trace”

Output

  • 4-20 mA - Chlorine Sensor with 3 Electrodes, Chlorine Sensor with 2 Electrodes
  • Analog: 0-2,000 mV, Max.

Pressure Range

  • psi: 0 to 14.5 (kPa: 0 to 100, bar: 0 to 1) - Max.
  • psi: 0 to 43.51 (kPa: 0 to 300, bar: 0 to 3) - Max.
  • psi: 0 to 7.25 (kPa: 0 to 50, bar: 0 to 0.5) - Max.

Process Temperature

  • 0° to 40° C (32° to 104° F) - Chlorine Sensor ”Trace”
  • 0° to 45° C (32° to 113° F) - Chlorine Sensor with 3 Electrodes, Chlorine Sensor with 2 Electrodes

Resolution

  • Sensor: 0.001 ppm - Chlorine Sensor ”Trace”
  • Sensor: 0.01 ppm - Chlorine Sensor with 3 Electrodes, Chlorine Sensor with 2 Electrodes

Response Time

  • t90: 120 seconds - Chlorine Sensor ”Trace”, Chlorine Sensor with 3 Electrodes
  • t90: 30 seconds - Chlorine Sensor with 2 Electrodes

Ring Material

  • Snap, Slide Ring: PETP

Shaft Material

  • PVC

Documentation

show more