Price
$2,155.00 CAD
Stock
25+ In Stock
Does not ship to OH, United States

  • Conductivity Probe - 2-Electrode
  • Cell Constant / Measuring Range - 0.01 cm-¹ / 0.05 to 20 µS/cm
  • Process Connection / Electrical Connection - 1-1/2" Clamp / 5-Pin M12 Male Connector

Specifications

Applications

  • Biotechnology
  • Food & Beverage
  • General Chemical Industry
  • Pharmaceutical

Approvals & Certifications

  • 2-Point Calibration Certificate
  • ECR 1935/2004 - 4-Electrode Conductivity Probe (Short or Long Insertion Version), 4-Electrode Conductivity Probe
  • Inspection Certificate 3.1
  • Test Report 2.2 - 2-Electrode Conductivity Probe with M12 Connector
  • USP Class VI Declaration - 4-Electrode Conductivity Probe (Short or Long Insertion Version), 4-Electrode Conductivity Probe

Approvals & Certifications

  • CE - 2-Electrode Conductivity Probe with M12 Connector
  • EHEDG - 4-Electrode Conductivity Probe
  • EU Directives - 2-Electrode Conductivity Probe with M12 Connector
  • FDA - 4-Electrode Conductivity Probe (Short or Long Insertion Version), 4-Electrode Conductivity Probe, 2-Electrode Conductivity Probe with M12 Connector
  • PED 2014/68/EU - 2-Electrode Conductivity Probe with M12 Connector

BSP Connection

  • G 1/4” Male
  • G 1-1/4” Male - 4-Electrode Conductivity Probe (Short or Long Insertion Version)

Electrical Connectors

  • 5-Pin M12 Male Fixed Connector - 2-Electrode Conductivity Probe with M12 Connector
  • Cable, Length 3 metres, Instrument Side with Open Wire - 2-Electrode Conductivity Probe with Cable
  • PG13.5 - 4-Electrode Conductivity Probe
  • VarioPin (VP 6.0) - 4-Electrode Conductivity Probe (Short or Long Insertion Version), 4-Electrode Conductivity Probe

Enclosure Finish

  • Electro-Polished

Environmental Protection

  • IP67 - 2-Electrode Conductivity Probe with M12 Connector

Linearity

  • Relative: ± 0.5 to 5 %

Materials of Construction

  • Electrode, Frame: 316L Stainless Steel - 4-Electrode Conductivity Probe (Short or Long Insertion Version) (1.4435), 4-Electrode Conductivity Probe (1.4435), 2-Electrode Conductivity Probe with M12 Connector
  • Electrode, Frame: Stainless Steel - 2-Electrode Conductivity Probe with Cable
  • Frame: PEEK - 4-Electrode Conductivity Probe (Short or Long Insertion Version), 4-Electrode Conductivity Probe, 2-Electrode Conductivity Probe with M12 Connector
  • Frame: PTFE - 2-Electrode Conductivity Probe with Cable

Measuring Range

  • 0.05 to 20 µS/cm - 2-Electrode Conductivity Probe with M12 Connector
  • 0.05 to 5,000 µS/cm - 2-Electrode Conductivity Probe with Cable
  • 0.1 to 500,000 µS/cm - 4-Electrode Conductivity Probe (Short or Long Insertion Version)
  • 1 to 500,000 µS/cm - 4-Electrode Conductivity Probe

Media

  • Water

Pressure Range

  • psi: 0 to 100 (kPa: 0 to 689.5, bar: 0 to 7) - Max.
  • psi: 0 to 87.06 (kPa: 0 to 600, bar: 0 to 6) - Max.

Process Temperature

  • 120° C (248° F) - Max.
  • -20° to 135° C (-4° to 275° F) - 4-Electrode Conductivity Probe (Short or Long Insertion Version), 4-Electrode Conductivity Probe
  • -20° to 150° C (-4° to 302° F) - 2-Electrode Conductivity Probe with M12 Connector

Response Time

  • t90: 60 seconds - 2-Electrode Conductivity Probe with M12 Connector

RTD Type

  • Pt1000

Seat / Seal Material

  • Seal: EPDM

Sensor, Probe Type

  • Probe: 2-Electrode - 2-Electrode Conductivity Probe with M12 Connector, 2-Electrode Conductivity Probe with Cable
  • Probe: 4-Electrode - 4-Electrode Conductivity Probe (Short or Long Insertion Version) & 4-Electrode Conductivity Probe

Tri-Clamp Connection

  • 1-1/2” Tri-Clamp - 4-Electrode Conductivity Probe (Short or Long Insertion Version), 2-Electrode Conductivity Probe with M12 Connector, 2-Electrode Conductivity Probe with Cable
  • 2” Tri-Clamp - 4-Electrode Conductivity Probe

Documentation

show more