Price
$1,293.00 CAD
Stock
50+ In Stock
Does not ship to OH, United States

  • Version - ATEX / IECEx Version
  • Circuit Function - G (4/2-Way Valve, Normally Pressure Port 1 Connected to Outlet 2, Outlet 4 Relieved)
  • Voltage - 110 V UC

Specifications

Ambient Temperature Range

  • 55° C (131° F) - Max.
  • Block Mounting: -30° to 50° C (-22° to 122° F) - ATEX/IECEx Version
  • Single Mounting: -30° to 60° C (-22° to 140° F) - ATEX/IECEx Version

Approvals & Certifications

  • Air Pressure Quality: ISO 8573-1: 2010, Class 7.4.4
  • CE
  • With Moulded Cable: IECEx PTB 14.0049 x (II 2 G Ex Mb IIC T5 Gb, II 2D Ex Mb IIIC T 100° C Db), with Junction Box: IECEx EPS 16.0021 x (II 2 G EX Eb Mb IIC T5 Gb, II 2D EX Mb Tb IIIC T100° C Db)
  • With Moulded Cable: PTB 14-ATEX-2023 x (II 2 G Ex Mb IIC T5 Gb, II 2D Ex Mb IIIC T 100° C Db), with Junction Box: EPS 16-ATEX-1046 x (II 2 G EX Eb Mb IIC T5 Gb, II 2D EX Mb Tb IIIC T100° C Db)

BSP Connection

  • G 1/4” Female
  • G 1/8” Male

Consumption

  • Power Consumption (Version with Vac): 11 VA (Inrush)
  • Power Consumption (Version with Vac): 6 VA (Hold)
  • Power Consumption (Version with Vdc): 2 W
  • Power: 3 W - ATEX/IECEx Version (NBR Seal & Moulded Cable)
  • Power: 5 W - ATEX/IECEx Version (NBR Seal & Junction Box)

Duty Cycle

  • 100 % Continuous Rating

Electrical Connectors

  • 3 metres Cable, Moulded - ATEX/IECEx Version
  • Junction Box (without Fuse), Moulded - ATEX/IECEx Version
  • Tag Connectors According to DIN EN 175301-803 (Previously DIN 43650) Form A for Cable Plug Typical 2508

Enclosure, Body Material

  • Polyamide (Reinforced)

Environmental Protection

  • IP65

Flow Rate

  • QNn-Value Air: 900 L/minute

Function

  • Circuit Function

Materials of Construction

  • Coil Material (Standard, Ex Version): Epoxy
  • Coil Material: Polyamide
  • Moulded-in Thread: Brass
  • Poppet: Plastic
  • Stopper, Magnet Core: 430FR Stainless Steel 1.4105

Media

  • Lubricated Compressed Air
  • Neutral Medium
  • Non-Lubricated Compressed Air

Mounting Position

  • Preferably with Solenoid System Upright

Operating Voltages

  • 24 Vdc
  • 24-230 V at 50/60 Hz
  • 24-230 VUC - ATEX/IECEx Version

Orifice Size

  • 6 mm

Pressure Range

  • psi: 14.5 to 145 (kPa: 100 to 1,000, bar: 1 to 10)

Process Temperature

  • -10° to 60° C (14° to 140° F)

Response Time

  • Closing: 30 milliseconds (Pressure Drop 100 to 10 %)
  • Opening: 50 milliseconds (Pressure Rise 0 to 90 %)

Seat / Seal Material

  • Core Seal: FKM
  • Seal Poppet: NBR

Solenoid Type

  • 4/2-Way

Tolerance

  • Voltage: ± 10 %
  • Voltage: 10 % - ATEX/IECEx Version

show more