Price
$4,819.00 CAD
Stock
50+ In Stock
Does not ship to OH, United States

  • Model - Solenoid Valve Type 6524 & 6525
  • Circuit Function - C (2 x 3/2-Way Solenoid Valve Servo-Assisted, Normally Closed, with Manual Override)
  • Pressure Range - bar: 2.5 to 10
  • Response Time - 12 milliseconds / 20 milliseconds

Specifications

Ambient Temperature Range

  • 0° to 55° C (32° to 131° F) - Pilot Valve Typical 0460, 6524, 6525

Approvals & Certifications

  • ATEX Zone 2 - Pilot Valve Typical 0460, 6524, 6525
  • IEC Ex Zone 2 - Pilot Valve Typical 0460, 6524, 6525

BSP Connection

  • G 1/4” Female - Pilot Valve Typical 0460

Communication

  • FOUNDATION FOUNDATION Fieldbus Typical: PROFIBUS DP - Pilot Valve Typical 0460, 6524, 6525
  • FOUNDATION Fieldbus Typical: PROFINET I/O - Pilot Valve Typical 0460, 6524, 6525

Current

  • Rated Current Per Valve: 20 mA - Pilot Valve Typical 0460
  • Rated Current Per Valve: 28 mA Hold Current after 120 milliseconds - Pilot Valve Typical 0460, 6524, 6525
  • Rated Current Per Valve: 40 mA - Pilot Valve Typical 0460, 6524, 6525

Diameter

  • 0.25” (6 mm) Push-In Connection - Solenoid Valve 6524 & 6525 (Pneumatic Module), Pilot Valve Typical 0460 (Service Port 2 (A), 4 (B))

Duty Cycle

  • Continuous Operation 100 % ED - Solenoid Valve 6524 & 6525

Electrical Connectors

  • At the Valve: Grid Spacing 2.54 mm - Solenoid Valve 6524 & 6525 (2 x 3/2-Way Valve)
  • At the Valve: Grid Spacing 5.08 mm - Solenoid Valve 6524 & 6525 (3/2 & 5/2-Way Valve)
  • At the Valve: Rectangular Plug - Pilot Valve Typical 0460
  • At the Valve: Rectangular Plug 2-Pin - Solenoid Valve 6524 & 6525 (3/2 & 5/2-Way Valve)
  • At the Valve: Rectangular Plug 3-Pin - Solenoid Valve 6524 & 6525 (2 x 3/2-Way Valve)

Electrical Contacts

  • Normally Closed - Solenoid Valve 6524 & 6525
  • Normally Open - Solenoid Valve 6524 & 6525

Enclosure, Body Material

  • Aluminum - Pilot Valve Typical 0460
  • Polyamide (PA) - Solenoid Valve 6524 & 6525

Environmental Protection

  • IP20 - Pilot Valve Typical 0460, 6524, 6525
  • IP65 - Pilot Valve Typical 0460, 6524, 6525

Flow Rate

  • 300 L/minute - Pilot Valve Typical 0460, 6524, 6525 & Solenoid Valve 6524, 6525
  • For Function H Impulse: 200 L/minute - Pilot Valve Typical 0460, 6524, 6525

Function

  • Circuit Function [C & D (3/2-Way), H (5/2-Way), H (5/2-Way) Impulse)] - Pilot Valve Typical 0460, 6524, 6525

Media

  • Compressed Air - Solenoid Valve 6524 & 6525, Pilot Valve Typical 0460
  • Dry - Solenoid Valve 6524 & 6525, Pilot Valve Typical 0460
  • Lubricated - Solenoid Valve 6524 & 6525, Pilot Valve Typical 0460
  • Neutral Gases (5 μm Filter) - Solenoid Valve 6524 & 6525, Pilot Valve Typical 0460
  • Oil Free - Solenoid Valve 6524 & 6525, Pilot Valve Typical 0460

Mounting

  • With 2 Screws M2 x 20 - Solenoid Valve 6524 & 6525 (3/2 & 5/2-Way Valve)
  • With 2 Screws M2 x 28 - Solenoid Valve 6524 & 6525 (2 x 3/2-Way Valve)

Mounting Position

  • Preferably with Actuator Upright - Solenoid Valve 6524 & 6525

Nominal Power

  • 1 W - Pilot Valve Typical 0460
  • Nominal Power Per Valve: 0.5 W According to 120 milliseconds - Pilot Valve Typical 0460, 6524, 6525
  • Nominal Power Per Valve: 0.8 W - Pilot Valve Typical 0460, 6524, 6525 & Solenoid Valve 6524, 6525 (3/2 & 5/2-Way Valve, 2 x 3/2-Way Valve - 2 Times)

NPT Connection

  • 1/4” NPT Female - Pilot Valve Typical 0460

Operating Voltages

  • 24 Vdc - Pilot Valve Typical 0460, 6524, 6525 & Solenoid Valve 6524, 6525 (10 % Residual Ripple Allowed)

Orifice Size

  • 2.5 mm - Pilot Valve Typical 0460
  • 4 mm - Solenoid Valve 6524 & 6525

Override

  • Manual Override - Solenoid Valve 6524 & 6525, Pilot Valve Typical 0460

Pressure Range

  • bar: -7 to 10
  • kPa: -700 to 1,000
  • psi: -101.5 to 145

Response Time

  • Closing: 2 to 28 milliseconds According to ISO 12238 - Solenoid Valve 6524 & 6525
  • Opening & Closing: 15 milliseconds According to ISO 12238 - Pilot Valve Typical 0460
  • Opening: 12 to 20 milliseconds According to ISO 12238 - Solenoid Valve 6524 & 6525

Seat / Seal Material

  • Seal: fpm - Solenoid Valve 6524 & 6525
  • Seal: NBR - Solenoid Valve 6524 & 6525, Pilot Valve Typical 0460
  • Seal: Polyurethane (PUR) - Solenoid Valve 6524 & 6525

Storage Temperature

  • -20° to 60° C (-4° to 140° F) - Pilot Valve Typical 0460, 6524, 6525

Tolerance

  • Voltage Tolerance: ± 10 % - Pilot Valve Typical 0460, 6524, 6525

Valves

  • Maximum

show more